Skip to content

Independent — not a factory service center

Jacksonville, FL Monday to Friday 8:00am – 6:00pm Saturday 9:00am – 4:00pm

Sheet index A-01

Sub-Zero repairs we take on

One manufacturer, diagnosed properly before it is quoted. $129 flat to diagnose, credited toward the repair, and 90 days on labor, 365 days on parts.

A technician in a dark work polo crouched low at an open built-in refrigerator, the rest of the kitchen — island, knife block, coffee machine — soft behind him.
P-10 One brand, one category, every sheet in this section
  • R-01

    Ice maker not producing

    No ice, short cubes or a harvest that never releases — and the one measurement that separates the two halves of the fault.

    • No ice at all after 24 hours with the arm down
    • Cubes come out hollow, short, or fused into a slab
    • The mold fills but the harvest never releases
  • R-02

    Refrigerator not cooling

    One compartment warm, the other cold — and why two sealed systems split the diagnosis in half.

    • Fresh food section warm while the freezer still holds
    • Both compartments drifting up together over several days
    • The compressor runs constantly and never cycles off
  • R-03

    Condenser and airflow service

    The maintenance job that prevents most sealed-system failures, and the local reasons it comes due sooner here.

    • The compressor runs almost continuously in summer
    • Warm air pouring from the grille above the door
    • Both compartments a few degrees above setpoint
  • R-04

    Door seal and condensation

    Water on the frame, frost in one corner, or a door that drifts open — the seal is doing less than it looks.

    • Water beading on the frame or the door face
    • Frost building in one upper corner of the freezer
    • The door swings back open unless it is pushed
  • R-05

    Wine storage temperature drift

    Stability matters more than the setpoint. What causes a zone to swing, and how we prove it over a full cycle.

    • The two zones no longer hold different temperatures
    • Corks pushing up, or seepage at the capsule
    • Condensation forming on the inside of the glass door
  • R-06

    Control and display faults

    A dead panel is not always a dead board. The supply-side checks that come before any control is replaced.

    • The display is blank but a fan or compressor still runs
    • Buttons respond intermittently or not at all
    • The setpoint resets itself after a power interruption
  • R-07

    Built-in installation and retrofit

    The measurements that decide whether a built-in fits, taken before the cabinet is ordered rather than after.

    • The rough opening is short by a fraction of an inch
    • No dedicated circuit within reach of the cabinet
    • Crown moulding or a soffit blocking the grille exhaust

Not listed

If the fault is not on this sheet, call and describe it. We will tell you on the phone whether it is ours to fix.

Call +1 (904) 977-8701